VeEX RXT-1200 stopper å boote
Min OTDR vil ikke komme lenger enn boot-screen. Hva gjør jeg nå?
Hei
Vil at du skal forsøke en software upgrade før vi gjør noe videre.
Gå til følgende adresser og last ned ny firmware. RXT-1200 oppdateres først som anvist under, dette blir å anse som en hard-reset. Software til OTDR modul oppdateres gjennom brukergrensesnittet etter at du har oppdatert plattformen.
RXT-1200
Updating the RXT Platform System Software (via USB) Warning:
The system update procedure reformats the platform’s internal storage and all results and profiles are erased. Please follow the procedure above to save all important files prior to updating the system software.
Once you have obtained and uncompressed the update package file (rxt1200-veex-arm.tar.gz), the firmware update procedure can be performed using a FAT32 USB Memory stick.
Note: If installed in your PC, some file compression agents (applications) may show the resulting rxt1200-veex-arm.tar.gz as a compressed file, but there is no need to expand the file anymore. Keep it as is.
-
Copy the uncompressed file to the root of the memory stick.
-
Plug the memory stick into one of the RXT-1200 platform’s USB ports.
-
Turn the power OFF and remove the test module.
-
Press the
(alt),
(enter) and
(power) buttons simultaneously. The three buttons can be released once the confirmation tone (beep) is heard. The system update procedure starts.
The update process will take a few minutes and the RXT will reboot itself at the end. The RXT-1200 must be connected to AC/DC charger at all times during the whole upgrade process. DO NOT turn it off at any time.
To verify the current software version number installed in the unit, open the Utilities section, select Settings, and open About.
Test modules may need to be updated to their latest software version available, to assure full compatibility.
RXT-4113
Updating the Test Module Software (via USB)
Make sure the RXT-1200 Platform is running the latest firmware version available. If the RXT Platform’s system software is already up-to-date and you have obtained and uncompressed the Test Module firmware update package file (rxt1200-otdr.tar.gz), the module update procedure can be performed using a FAT32 USB Memory stick.
-
Copy the test module’s uncompressed firmware update package file to the root of the memory stick.
-
Plug it into one of the RXT-1200 platform’s USB ports.
-
Turn the power OFF and insert the test module.
-
Turn the RXT Platform ON and wait for the boot up process to finish.
-
The RXT may display an “incompatible software version” warning message to indicate that the test module requires a firmware update. Tap the OK button to close the message.
-
Touch the V or Utilities button on the top bar, open the Utilities tab on the left bar, and select M.Upgrade.
-
The RXT will search the memory stick for valid update packages and show its information.
-
Tap on the Upgrade button to start the firmware update process. This could take several minutes. The RXT will shut itself off at the end.
The RXT-1200 must be connected to AC/DC charger at all times during the whole upgrade process. DO NOT turn it off at any time; the update process would take a few minutes and RXT will reboot itself at the end.
To verify the software version number installed in the current test module, turn the RXT back on, open the Utilities section, select Settings, and open About. The firmware update package files for multiple test modules can be copied to the USB memory stick at once, but each module must be updated separately, by plugging one module at a time and following the procedure listed above.